home > 5461-644 Woodward 16-Point High-Density Analog Unit > 5461-644 Woodward 16-Point High-Density Analog Unit
download picture
5461-644 Woodward 16-Point High-Density Analog UnitProduct Overview The Woodward 5461 644 serves as a high density Analog Input module for the MicroNet Digital Control System. It provides 16 isolated channels that convert critical analog signalssuch as pressure, temperature, and flowinto digital data for the MicroNet CPU. This module facilitates precise monitoring and protection functions for gas turbines, steam turbines, and large industrial engines. By supporting multiple signal types and providing
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Woodward 5461-644 serves as a high-density Analog Input module for the MicroNet Digital Control System. It provides 16 isolated channels that convert critical analog signals—such as pressure, temperature, and flow—into digital data for the MicroNet CPU. This module facilitates precise monitoring and protection functions for gas turbines, steam turbines, and large industrial engines. By supporting multiple signal types and providing robust galvanic isolation, the 5461-644 ensures data integrity in electrically noisy power generation and mechanical drive environments.

Condition: This product is 100% Brand New, original factory sealed, and includes a full 1-year warranty.

Technical Specifications

The 5461-644 utilizes high-resolution A/D conversion logic to maintain accuracy across fluctuating industrial temperatures.

Parameter Details
Manufacturer Woodward
Model Number 5461-644
Input Channels 16 Isolated Analog Inputs
Signal Compatibility 4–20 mA Current Loop, ±10 VDC Voltage
A/D Resolution 12–16 Bit (Software Configurable)
Accuracy ±0.5% of Full Scale
Isolation Optical and Electrical (Channel-to-Bus)
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +100°C
Indicators Front-panel LEDs (Health & Channel Activity)
Backplane Interface Standard MicroNet VME-based Chassis Bus
Weight 1.0 kg

Engineering Advantages

  • Dual Signal Versatility: The module handles both 4–20 mA and ±10 VDC inputs. This flexibility allows engineers to standardize on a single card type for diverse instrumentation needs, significantly reducing spare parts inventory.

  • Superior Noise Rejection: High-integrity optical and electrical isolation barriers protect the logic side from field-side interference. This feature eliminates ground loop errors and prevents high-voltage transients from damaging the central processing unit.

  • High-Density Rack Integration: By providing 16 channels in a single slot, the 5461-644 maximizes rack space. This density proves critical in offshore or mobile turbine enclosures where cabinet space remains at a premium.

  • Extreme Thermal Resilience: With an operating range of -40°C to +85°C, this module thrives in unconditioned environments. The hardware maintains its calibration curve even during rapid thermal cycling, ensuring consistent protection for the turbine.

  • Instantaneous Diagnostics: Front-panel LEDs provide immediate status for each channel. This allows technicians to distinguish between a sensor failure, a wiring break, or a module fault without specialized diagnostic software.

FAQs

  • Can the 5461-644 handle 2-wire and 4-wire transmitters?

    Yes. The module integrates into the MicroNet FTM (Field Terminal Module) system, which supports various wiring configurations for both loop-powered (2-wire) and self-powered (4-wire) analog transmitters.

  • How does the module ensure data accuracy over time?

    The module features onboard reference stability checks. While Woodward factory-calibrates the unit, we recommend periodic system-level loop checks to account for field sensor drift and wiring resistance changes.

  • Is the 5461-644 compatible with MicroNet Plus and MicroNet HD racks?

    Yes. This module follows the standard MicroNet VME architecture, making it compatible with the majority of MicroNet chassis variations. Always verify slot keying before installation.

  • Does this module support "hot-swapping" during turbine operation?

    While the MicroNet chassis provides hardware support, "hot-swapping" an analog input module during live operation may trigger safety trips if the signals are used in active control loops. Always consult your specific turbine application logic before removing any I/O card.

5461-644 Woodward 16-Point High-Density Analog Unit

Item no : 21128902629
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 4 - Jul 9

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches