Endress+Hauser 9E1B Flow Measurement Proline Prosonic Flow E 100 Ultrasonic FlowmeterOverview Endress+Hauser Proline Prosonic E100 Ultrasonic Flowmeter is an economical Ultrasonic flowmeter with integrated temperature measurement. Specs at a glance * Max. measurement error Volume flow (standard): 1. 0 % o. r. for 3 to 40 m s (9. 84 to 131. 23 ft s) 2 % o. r. for 0. 3 to 3 m s (0. 98 to 9. 84 ft s) Volume flow (optional calibration): 0. 5 % o. r. for 3 to 40 m s (9. 84 to 131. 23 ft s) 1. 0 % o. r. for 0. 3 to 3 m s (0. 98 to 9. 84 ft
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview

Endress+Hauser Proline Prosonic E100 Ultrasonic Flowmeter is an economical Ultrasonic flowmeter with integrated temperature measurement.

Specs at a glance

* Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
* Measuring range :Gas: 0.3 m/s to 40 m/s
* Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell
* Max. process pressure : 0.7 to 101 bar a (10.15 to 1464.88 psi a)
* Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2


 

Benefits

 * Flexible device with user-definable gas mixtures for demanding measuring tasks
* Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
* High-performance process control – real-time pressure- and temperature-compensated values
* Efficient solution – multivariable, no pressure loss
* Full access to process and diagnostic information – numerous, freely combinable I/Os
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology

Application

For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.

* The measuring principle is unaffected by gas composition
* Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.

Device properties:
* Direct measurement: flow, pressure & temperature
* Wetted parts: titanium / 316L
* Maximum measuring accuracy: 0.5 %
* Compact dual-compartment housing with up to 3 I/Os
* Backlit display with touch control and WLAN access
* Remote display available

Specification

Measuring principle Ultrasonic flow
Product headline Highly robust gas specialist for fluctuating process conditions with compact, easily accessible transmitter.
Flexible device with user-definable gas mixtures for demanding measuring tasks.
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Sensor features Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control –
real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss.
Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %.
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely
configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 25 to 300 (1 to 12")
Wetted materials Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2
Measured variables Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity,
energy flow, Wobbe index, methane fraction, calorific value, molar mass
Max. measurement error Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
Measuring range Gas: 0.3 m/s to 40 m/s
Max. process pressure 0.7 to 101 bar a (10.15 to 1464.88 psi a)
Medium temperature range -50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell
Ambient temperature range -40 to 60 °C(-40 to +140 °F)
Optional: -50 to 60 °C(-58 to +140 °F)
Sensor housing material Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Polycarbonate
Degree of protection Compact version: IP66/67, type 4X enclosure.
Optional: External WLAN antenna: IP67
Display/Operation 4-line backlit display with Touch Control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, Modbus RS485
Power supply 24V DC
100 to 230 V AC
AC 100 to 230 V / DC 24 V (non harzardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
Product safety CE, C-tick
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
NACE MR0175/MR0103

Endress+Hauser 9E1B Flow Measurement Proline Prosonic Flow E 100 Ultrasonic Flowmeter

Item no : 27098959130
sold recently : Login >>
US$ 624.38
Pay in 4 interest-free payments of $156.09 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 30 - Jul 5

Enjoy 20% off shipping

US$ 624.38

1-11

US$ 561.94

12-35

US$ 437.07

36-59

US$ 374.63

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches