The Allen-Bradley 1756-OF8 provides high-precision analog signal generation for the ControlLogix platform. This module converts digital PLC data into accurate voltage or current signals to drive valves, motor drives, and chemical feed pumps. Each of the 8 channels operates independently, allowing for mixed-signal environments within a single chassis slot. We supply this unit as 100% Brand New and Original in factory packaging, ensuring the highest calibrated accuracy for your mission-critical process loops.
| Specification | Details |
| Number of Outputs | 8 Voltage or Current Channels |
| Output Ranges | ±10V, 0–10V, 0–5V; 0–20 mA, 4–20 mA |
| Resolution | 15 Bits |
| Calibrated Accuracy | Better than 0.05% of range |
| Settling Time | < 2 ms (to 95% of final value) |
| Backplane Power | 5.8 Watts |
| Current Draw | 150 mA @ 5.1V; 210 mA @ 24V |
| Thermal Dissipation | 16.78 BTU/hr |
| Isolation Voltage | 250V Continuous (Channel-to-Backplane) |
| Protection | 24V DC Overvoltage; Electronic Current Limiting (21 mA) |
Exceptional Signal Precision: The 15-bit resolution ensures ultra-smooth control increments. This precision eliminates "stepping" in valve positioning, which significantly reduces mechanical wear on final control elements and improves process stability.
Rapid Response Times: A settling time of less than 2 ms allows the module to track dynamic setpoint changes instantly. This speed makes the 1756-OF8 ideal for high-speed tension control or hydraulic pressure regulation where milliseconds matter.
Built-in Circuit Protection: The module incorporates electronic current limiting and 24V DC overvoltage protection. These safety features prevent a single faulty actuator or a field wiring short from damaging the entire module or the ControlLogix backplane.
Comprehensive Diagnostics: The 1756-OF8 detects open-circuit conditions in current loops (at settings >0.1 mA). This immediate feedback allows maintenance teams to identify broken field wires or failed coils without manual loop testing, reducing Mean Time to Repair (MTTR).
Which Removable Terminal Block (RTB) should I use with the 1756-OF8?
The 1756-OF8 requires a 20-pin RTB. You should use the 1756-TBNH (NEMA screw clamp) or the 1756-TBSH (Spring clamp). Always verify that the RTB is seated correctly and locked before applying field power.
Can I mix voltage and current outputs on the same module?
Yes. You configure each channel individually via the Studio 5000 software. You can drive a variable frequency drive (VFD) via a 0-10V signal on Channel 0 while simultaneously controlling a proportional valve via a 4-20mA loop on Channel 1.
What happens to the outputs if the controller enters Program Mode or a Fault state?
The 1756-OF8 features configurable "Hold Last State" or "Go to Safe Value" settings. You can program each channel to drop to 0mA/0V, hold its last commanded position, or move to a specific user-defined safety value to ensure the process remains in a safe condition during a CPU halt.
Is external 24V DC power required?
The 1756-OF8 draws its power directly from the ControlLogix backplane (both the 5.1V and 24V rails). It does not require a separate external power supply for the module logic, though your field actuators may require their own independent power sources.